Back to In the Wild

DISTO family

DISTO Error Code Index

By bwauters

|
03/07/2019

This blog contains DISTO error codes for all models. If your error code is unlisted or if you are unable to resolve using the corrective methods below, please contact your dealer for more information.

Error 156: The transverse tilt is greater than +/- 10°
To resolve: Hold the instrument without any transverse tilt


Error 162: Calibration mistake
To resolve: Make sure the device is placed on an absolutely horizontal and flat surface. Repeat the calibration procedure. If the message still occurs, contact the dealer 


Error 204: Calculation error
To resolve: Repeat measurements, make sure to follow the sequence according to the manual


Error 205: S910 memory full
To resolve: Delete memory


Error 220 & 224: Hardware error
To resolve: If the message continuously appears, contact the dealer for service


Error 240 & 245: Data transfer error
To resolve: Re-connect device with computer and repeat procedure


Error 252: Temperature too high
To resolve: Let device cool down


Error 253: Temperature too low
To resolve: Let device warm up


Error 254: Battery voltage too low for measurements
To resolve: Change batteries


Error 255: Received signal too weak, measuring time too long
To resolve: Change target surface (i.e. white paper)


Error 256: Received signal too high
To resolve: Change target surface (i.e. white paper)


Error 257: Too much background light
To resolve: Shadow target area


Error 258: Measuring outside of measuring range
To resolve: Correct range


Error 260: Laser beam interrupt
To resolve: Repeat measurement


Error 284: Laser defect
To resolve: If message continuously appears, contact the dealer for service


Error 288-294: Hardware error
To resolve: If message continuously appears, contact the dealer for service


Error 300: Smart base not folded out
To resolve: Fold out Smart Base


Error 301: Device was moved, levelling not valid anymore
To resolve: Perform levelling again. Levelling with invalid levelling is possible, but it will affect the accuracy


Error 302: S910 "Point data transmission" is selected, but WLAN is off
To resolve: Switch on WLAN


Error 303 - 306: Error with Leica DST 360 Adapter
To resolve: Repeat procedure and if message still occurs, contact your dealer


Error 340: WLAN: Data transfer error
To resolve: Repeat procedure


Error 341: Authentication error
To resolve: Use correct password


Error >1000: Hardware error
To resolve: If message continuously appears, contact the dealer for service


Error 14041: Smart Base defect
To resolve: If message continuously appears, contact the dealer for service


If your error code is unlisted, please contact your dealer for service.

 

Share:

Explore Comments

Comments

lindsay.walker Wed, 01/22/2020

In reply to by Noe Paredes (not verified)

Permalink

Hi Noe,

Error 290 is a measuring module error and you should contact your dealer to resolve.

Salvador Franc… (not verified) Sat, 08/15/2020

In reply to by Noe Paredes (not verified)

Permalink

Tengo el disto D210 y me sale error 290. Que es? Puedo solucionarlo?

Davis (not verified) Tue, 12/10/2019 Permalink

I have a 224 error code on disto x4 model. The device does not work anymore, I would like to know the problem.
Thank you

lindsay.walker Wed, 01/22/2020

In reply to by Davis (not verified)

Permalink

Hi Davis,

The error 224 with the X4 is indicating a communication error, and the remedy is for the user to perform the reset function with the unit. If this does not allow the X4 to operate without getting the error the unit will need to be replaced.

Arturo (not verified) Mon, 01/27/2020 Permalink

Al intentar medir inclinación siempre sale error 156
Que está ocurriendo
En el A8 no significa inclinación transversal excesiva eso sería error 155 el 156 que me sale, no aparece en el manual

lindsay.walker Fri, 02/28/2020

In reply to by Arturo (not verified)

Permalink

Hi Arturo, error 156 is Transverse tilt > 10°. If you are unable to resolve this code you will want to submit a support ticket on MyWorld so that a specialist can work through this with you.

Jürgen Ahlers (not verified) Wed, 02/12/2020 Permalink

What do error codes 52 and 84 of a Leica geodimeter (here TC 403) mean ???
I would be happy if I got an answer!!!
Sincerely yours
Jürgen Ahlers

MOHAMMED (not verified) Mon, 04/20/2020 Permalink

Error 255
I used the dashboard and special recommendations, but the same error is repeated and does not give any measurement

lindsay.walker Wed, 05/06/2020

In reply to by MOHAMMED (not verified)

Permalink

Hi Mohammed,
If the error is not resolved by measuring from a shorter distance or from using a target plate, I would recommend submitting a support ticket on MyWorld by selecting "Get Support."

A technical specialist will be in touch and will able to help resolve this issue.

David A. Dwyer… (not verified) Mon, 04/27/2020 Permalink

I have the D5 model and recently it will not read distances and will only display 255 error. it was working and suddenly stopped. Is there a reset on this or is it just dead?

Hi David,
This can vary case by case. I would recommend submitting a ticket on MyWorld:
select "Get Support" and a technical rep will be in touch with you asap. They will be able to provide you guidance with your D5.

Eder (not verified) Tue, 05/12/2020 Permalink

Was bedeutet der Fehlercode 289 bei Disto D3a?

Vielen Dank!

Sergio Fauceglia (not verified) Fri, 05/22/2020 Permalink

Errore 255 nella lettura della distanza ... cosa fare ..?

damien (not verified) Sat, 09/05/2020 Permalink

Bonjour, j'ai un code Erreur 224. Tout fonctionne SAUF le laser. J'ai lu qu'un reset était possible. Est ce vrai
? L'appareil n'est jamais tombé et n'a subi aucun dommage . Merci

Hi there, I would recommend reaching out to whomever you purchased the device from. A reset is possible in most cases, but it will depend on the model/age/make of the device. You can also submit a ticket via MyWorld in order to speak with a technical representative who will have insight on the error code and can help with the reset.

STAEBLER Philippe (not verified) Mon, 12/07/2020 Permalink

Rien à faire pour mon Disto D5 L'erreur 255 est permanente. Que faire ?

Matteo (not verified) Thu, 12/10/2020 Permalink

Hi, i've some problem with my Disto D2, it continue to "beep" while is on, don't shut off, and don't take the measurement.
What can be?

shamsedin (not verified) Tue, 12/22/2020 Permalink

I have the D5 model and recently it will not read distances and will only display 255 error please guide me

Ken (not verified) Thu, 12/31/2020 Permalink

Older model. Error code i255. I stopped using it for about a year because of the error code. One day I put in new batteries and it worked. No batteries were in during non use. Used it for about 10 months and because batteries were low I replaced them. Now it again only shows i255. tried new batteries and cleaned the lens. no change.
Any recommendations?

Add new comment